• xthexder@l.sw0.com
    link
    fedilink
    English
    arrow-up
    28
    ·
    3 个月前

    The actual method for calibrating exact resistor values involves starting with a lower resistance and etching away parts of it with a laser to get to the exact value you want. You probably still couldn’t get as many decimal places as OP tho

    • trolololol@lemmy.world
      link
      fedilink
      English
      arrow-up
      39
      ·
      3 个月前

      And then in a week it drifts into a different value and you have to calibrate it again.

      And that’s assuming your room temperature is controlled for all experiments.

      And that’s also assuming the current going through it is 0 so it is always exactly at room temperature.

      Virgin theoretical physicist vs Chad experimental physicist goes brrr

      • xthexder@l.sw0.com
        link
        fedilink
        English
        arrow-up
        16
        ·
        3 个月前

        For really sensitive applications like voltage references, they actually build a little enclosure around the part with a built in heater to keep it at a constant calibrated temperature. The boards also often have cutouts to reduce thermal transfer and things like the board flexing causing stress to the part.

        The resistor itself won’t really drift at a constant temperature, especially in a sealed environment where condensation, corrosion, and dust aren’t a factor.

      • sepi@piefed.social
        link
        fedilink
        English
        arrow-up
        10
        ·
        3 个月前

        As a layperson, what happens if crumbs from my sandwich fall all over your chad experiment setup?